BMC Oral Health (Nov 2023)

Application of a modified osteotomy and positioning integrative template system (MOPITS) based on a truncatable reconstruction model in the precise mandibular reconstruction with fibula free flap: a pilot clinical study

  • Qing Sun,
  • Zhihui Zhu,
  • Fanhao Meng,
  • Ruiqi Zhao,
  • Xing Li,
  • Xiao Long,
  • Yansheng Li,
  • Haitao Dong,
  • Tao Zhang

DOI
https://doi.org/10.1186/s12903-023-03596-6
Journal volume & issue
Vol. 23, no. 1
pp. 1 – 10

Abstract

Read online

Abstract Background Mandibular defects can greatly affect patients' appearance and functionality. The preferred method to address this issue is reconstructive surgery using a fibular flap. The current personalized guide plate can improve the accuracy of osteotomy and reconstruction, but there are still some problems such as complex design process and time-consuming. Therefore, we modified the conventional template to serve the dual purpose of guiding the mandible and fibula osteotomy and facilitating the placement of the pre-bent titanium. Methods The surgery was simulated preoperatively using Computer-Aided Design (CAD) technology. The template and truncatable reconstruction model were produced in the laboratory using 3D printing. After pre-bending the titanium plate according to the contour, the reconstruction model was truncated and the screw trajectory was transferred to form a modified osteotomy and positioning integrative template system (MOPITS). Next, the patient underwent a composite template-guided vascularized fibula flap reconstruction of the mandible. All cases were reviewed for the total operative time and accuracy of surgery. Results The procedures involved 2–4 fibular segments in 15 patients, averaging 3 fibular segments per procedure. The osteotomy error is 1.01 ± 1.02 mm, while the reconstruction angular error is 1.85 ± 1.69°. The preoperative and postoperative data were compared, and both p > 0.05. During the same operation, implant placement was performed on four patients, with an average operative time of 487.25 ± 60.84 min. The remaining malignant tumor patients had an average operative time of 397.18 ± 73.09 min. The average postoperative hospital stay was 12.95 ± 3.29 days. Conclusions This study demonstrates the effectiveness of MOPITS in facilitating precise preoperative planning and intraoperative execution of fibula flap reconstruction. MOPITS represents a promising and reliable tool for reconstructive surgery, particularly for inexperienced surgeons navigating the challenges of mandible defect reconstruction.

Keywords