Asia Oceania Journal of Nuclear Medicine and Biology (Oct 2013)

Subcutaneous Extravasation of Sr-89: Usefulness of Bremsstrahlung Imaging in Confirming Sr-89 Extravasation and in the Decision Making for the Choice of Treatment Strategies for Local Radiation Injuries Caused by Sr-89 Extravasation

  • Joji Kawabe,
  • Shigeaki Higashiyama,
  • Kohei Kotani,
  • Atsushi Yoshida,
  • Hiroyuki Tsushima,
  • Takashi Yamanaga,
  • Daisuke Tsuruta,
  • Susumu Shiomi

Journal volume & issue
Vol. 1, no. 2
pp. 56 – 59

Abstract

Read online

A male patient in his 20s presented at our clinic with pain caused by bone metastases of the primitive neuroectodermal tumor, and Sr-89 was administrated to palliate the pain. After receiving the injection, the patient complained of a slight burning pain at the catheterized area. Slight reddening and small circular swelling (diameter, 0.5 cm) were observed at the catheterized area. Sr-89 extravasation was suspected. To estimate the amount of subcutaneous Sr-89 leakage, bremsstrahlung imaging was immediately performed. We speculated that the skin-absorbed dose from the subcutaneous Sr-89 leakage was 1.78 Gy. The mildest clinical sign of local radiation injury was erythema. The received dose was higher than 3 Gy, and the time of onset was from 2 to 3 weeks. In our patient, local radiation injuries (LRIs) did not occur. Though requiring further verification, subsequent bremsstrahlung imaging and estimation of the skin-absorbed dose from the subcutaneous Sr-89 leakage are useful in confirming Sr-89 extravasation and in the decision making for the choice of treatment strategies for LRIs caused by Sr-89 extravasation.