Radiation Protection and Environment (Jan 2020)

Establishment of pediatric local diagnostic reference levels for intraoral radiography

  • Amal Jose,
  • A Saravana Kumar,
  • K N Govindarajan,
  • P Manimaran

DOI
https://doi.org/10.4103/rpe.RPE_9_20
Journal volume & issue
Vol. 43, no. 2
pp. 77 – 81

Abstract

Read online

The objective of the present study is to propose a set of regional diagnostic reference levels (DRLs) for pediatric intraoral (IO) radiography procedures classified by IO examinations in Tamil Nadu, India. Of the 120 total units, 60 were digital and the remaining 60 units used film as image receptors. The third quartile values obtained for the selected IO examinations ranged from 1.05 mGy for the mandibular incisors to 1.48 mGy for the maxillary molars. The DRLs of the present study compare well with other International published DRLs. Following this primary study, DRLs will be proposed for other regions of the country, to arrive at national DRLs for pediatric IO dentistry.

Keywords