Sensors (Nov 2021)
Elements Influencing sEMG-Based Gesture Decoding: Muscle Fatigue, Forearm Angle and Acquisition Time
Abstract
The surface Electromyography (sEMG) signal contains information about movement intention generated by the human brain, and it is the most intuitive and common solution to control robots, orthotics, prosthetics and rehabilitation equipment. In recent years, gesture decoding based on sEMG signals has received a lot of research attention. In this paper, the effects of muscle fatigue, forearm angle and acquisition time on the accuracy of gesture decoding were researched. Taking 11 static gestures as samples, four specific muscles (i.e., superficial flexor digitorum (SFD), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL) and finger extensor (FE)) were selected to sample sEMG signals. Root Mean Square (RMS), Waveform Length (WL), Zero Crossing (ZC) and Slope Sign Change (SSC) were chosen as signal eigenvalues; Linear Discriminant Analysis (LDA) and Probabilistic Neural Network (PNN) were used to construct classification models, and finally, the decoding accuracies of the classification models were obtained under different influencing elements. The experimental results showed that the decoding accuracy of the classification model decreased by an average of 7%, 10%, and 13% considering muscle fatigue, forearm angle and acquisition time, respectively. Furthermore, the acquisition time had the biggest impact on decoding accuracy, with a maximum reduction of nearly 20%.
Keywords