Asian Spine Journal (Feb 2019)
Feasibility of Sub-Axial Cervical Laminar Screws, Including C7, in the Indian Population: A Study on 50 Patients Using Computed Tomography-Based Morphometry Measurements
Abstract
Study Design Observational study of computed tomography (CT) data. Purpose We performed a CT-based radiographic analysis of sub-axial cervical lamina in the Indian population to assess the feasibility of laminar screws. Overview of Literature Morphometric studies have been performed for populations of various ethnic groups, but none exist for Indian populations. Methods Cervical spine CT scans of 50 adults with a minimum slice thickness of <2 mm (0.5–2 mm) were obtained from the database of a single center in northern India. Measurements (e.g., length, thickness, and height) were taken in millimeters along the axial, coronal, and sagittal planes. Three measurements were made to assess laminar anatomy, namely, the translaminar/screw length, laminar thickness, and sagittal laminar height. Results The final sample comprised 500 laminae in 50 patients, resulting in 1,500 measurements. The mean translaminar lengths of the C3, C4, C5, C6, and C7 laminae were 19.48 mm, 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.60 , 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.61 , 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 20.49 , 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, and 22.85 mm, respectively. The mean thick- , and 22.85 mm, respectively. The mean thick , and 22.85 mm, respectively. The mean thicknesses of these cervical laminae were 3.12 mm, 2.62 mm, 2.56 mm, 3.47 mm, and 5.20 mm, respectively. The mean sagittal heights of these laminae were 9.38 mm, 9.80 mm, 10.12 mm, 11.31 mm, and 13.84 mm, respectively. Except for the C7 vertebrae, all other levels had a success rate of <10% in the Indian population using the criteria of a laminar height of at least 9 mm and thickness of 4.5 mm. Limited success was achieved at the C5, C6, and C3 levels. Conclusions To the best of our knowledge, the present study is the only series on the feasibility of laminar screws in the sub-axial cervical spine in the Indian population. We found that Indian patients have smaller anatomical dimensions and thus, are not suitable for laminar screws in the sub-axial cervical spine, barring C7, which is contrary to findings for populations in western and south Asian countries.
Keywords