BMC Medical Imaging (Dec 2017)
Lesion based diagnostic performance of dual phase 99mTc-MIBI SPECT/CT imaging and ultrasonography in patients with secondary hyperparathyroidism
Abstract
Abstract Background We aimed to evaluate the diagnostic performance of 99mTc-MIBI SPECT/CT and ultrasonography in patients with secondary hyperparathyroidism (SHPT), and explored the factors that affect the diagnostic performance. Methods 99mTc-MIBI SPECT/CT and ultrasonography were performed in 50 patients with SHPT within 1 month before they underwent surgery. Imaging results were confirmed by the pathology. Pearson correlation analysis was used to determine the correlation of PTH level with clinical data. The optimal cutoff value for predicting positive 99mTc-MIBI results was evaluated by ROC analysis in lesions diameter. Results Forty-nine patients had a positive 99mTc-MIBI imaging results and 39 patients had positive ultrasonography results. The sensitivities of 99mTc-MIBI and ultrasonography were 98.00% and 78.00%, respectively. A total of 199 lesions were resected in 50 patients. Among them, 183 lesions were proved to be parathyroid hyperplasia. On per-lesion basis analysis, the sensitivity and specificity of 99mTc-MIBI and ultrasonography were 59.34% and 75.00% vs 46.24% and 80.00%, respectively. The Pearson correlation analysis showed that the serum AKP and PTH level had a significant linear association (r = 0.699, P < 0.001). The lesion diameter was a statistically significant predictive factor in predicting positive 99mTc-MIBI SPECT/CT. The optimal cutoff value for predicting positive 99mTc-MIBI results evaluated by ROC analysis in lesions diameter was 8.05 mm. Conclusion Dual phase 99mTc-MIBI SPECT/CT imaging had a higher sensitivity in patients with SHPT than ultrasonography. Therefore, using 99mTc-MIBI positioning the lesion could be an effective method pre-surgical in patients with SHPT.
Keywords