BMC Anesthesiology (May 2022)

Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery

  • Qian Ma,
  • Jingjing Ji,
  • Xueduo Shi,
  • Ziyun Lu,
  • Lu Xu,
  • Jing Hao,
  • Wei Zhu,
  • Bingbing Li

DOI
https://doi.org/10.1186/s12871-022-01692-8
Journal volume & issue
Vol. 22, no. 1
pp. 1 – 8

Abstract

Read online

Abstract Background The volume status of patients after major abdominal surgery constantly varies owing to postoperative diverse issues comprising fluid loss or capillary leakage secondary to systemic inflammatory reaction syndrome, et.al, the precise fluid responsiveness assessment is crucial for those patients. The purpose of this study is to validate the transthoracic ultrasonographic measurement of superior and inferior vena cava variation in predicting fluid responsiveness of mechanically ventilated patients after surgery. Methods A total of 70 patients undergoing the scheduled major abdominal surgeries in the anesthesia ICU ward were included. The superior vena cava (SVC) collapsibility index (SVCCI), the inferior vena cava distensibility index (dIVC), SVC variation over the cardiac cycle (SVCV), and cardiac output (CO) were measured by transthoracic ultrasonography were recorded before and after fluid challenge test of 5 ml/kg crystalloid within 15 min. The responders were defined as a 15% or more increment in CO. Results Thirty patients (42.9%) responded to fluid challenge, while the remnant forty patients (57.1%) did not. The areas under the ROC curve (AUC) of SVCCI, dIVC and SVCV were 0.885 (95% CI, 0.786–0.949; P < 0.0001) and 0.727 (95% CI, 0.608–0.827; P < 0.001) and 0.751 (95% CI, 0.633–0.847; P < 0.0001), respectively. AUCdIVC and AUCSVCV were significantly lower when compared with AUCSVCCI (P < 0.05). The optimal cutoff values were 19% for SVCCI, 14% for dIVC, and 15% for SVCV. The gray zone for SVCCI was 20%-25% and included 15.7% of patients, while 7%-27% for dIVC including 62.9% of patients and 9%-21% for SVCV including 50% of patients. Conclusion Superior vena cava-related parameters measured by transthoracic ultrasound are reliable indices to predict fluid responsiveness. The accuracy of SVCCI in mechanically ventilated patients after abdominal surgery is better than that of dIVC and SVCV. Trial registration ChiCTR-INR-17013093 . The initial registration date was 24/10/2017.

Keywords