Metrology and Measurement Systems (Jun 2022)

An improved algorithm for the series step-up method based on a linear three-ports network

  • Hao Liu,
  • Lixue Chen,
  • Xue Wang,
  • Teng Yao,
  • Xiong Gu

DOI
https://doi.org/10.24425/mms.2022.140035
Journal volume & issue
Vol. vol. 29, no. No 2
pp. 301 – 313

Abstract

Read online

Capacitive leakage and adjacent interference are the main influence sources of the measuring error in the traditional series step-up method. To solve the two problems, a new algorithm was proposed in this study based on a three-ports network. Considering the two influences, it has been proved that response of this three-ports network still has characteristics of linear superposition with this new algorithm. In this threeport network, the auxiliary series voltage transformers use a two-stage structure that can further decrease measurement uncertainty. The measurement uncertainty of this proposed method at 500/√3 kV is 6.8 ppm for ratio error and 7 μrad for phase displacement ( k = 2). This new method has also been verified by comparing its results with measurement results of the PTB in Germany over the same 110/√3 kV standard voltage transformer. According to test results, the error between the two methods was less than 2.7 ppm for ratio error and 2.9 μrad for phase displacement.

Keywords