Abstract

Read online

Abstract Objective To compare the diagnostic power among various machine learning algorithms utilizing multi-sequence magnetic resonance imaging (MRI) radiomics in detecting anterior cruciate ligament (ACL) tears. Additionally, this research aimed to create and validate the optimal diagnostic model. Methods In this retrospective analysis, 526 patients were included, comprising 178 individuals with ACL tears and 348 with a normal ACL. Radiomics features were derived from multi-sequence MRI scans, encompassing T1-weighted imaging and proton density (PD)-weighted imaging. The process of selecting the most reliable radiomics features involved using interclass correlation coefficient (ICC) testing, t tests, and the least absolute shrinkage and selection operator (LASSO) technique. After the feature selection process, five machine learning classifiers were created. These classifiers comprised logistic regression (LR), support vector machine (SVM), K-nearest neighbors (KNN), light gradient boosting machine (LightGBM), and multilayer perceptron (MLP). A thorough performance evaluation was carried out, utilizing diverse metrics like the area under the receiver operating characteristic curve (ROC), specificity, accuracy, sensitivity positive predictive value, and negative predictive value. The classifier exhibiting the best performance was chosen. Subsequently, three models were developed: the PD model, the T1 model, and the combined model, all based on the optimal classifier. The diagnostic performance of these models was assessed by employing AUC values, calibration curves, and decision curve analysis. Results Out of 2032 features, 48 features were selected. The SVM-based multi-sequence radiomics outperformed all others, achieving AUC values of 0.973 and 0.927, sensitivities of 0.933 and 0.857, and specificities of 0.930 and 0.829, in the training and validation cohorts, respectively. Conclusion The multi-sequence MRI radiomics model, which is based on machine learning, exhibits exceptional performance in diagnosing ACL tears. It provides valuable insights crucial for the diagnosis and treatment of knee joint injuries, serving as an accurate and objective supplementary diagnostic tool for clinical practitioners.

Keywords