Pribory i Metody Izmerenij (Mar 2015)

CHOOSING OF OPERATING FREQUENCY OF EDDY CURRENT THICKNESS METER WITH SUPERIMPOSED TRANSDUCER

  • A. V. Chernyshev

Journal volume & issue
Vol. 0, no. 1
pp. 73 – 78

Abstract

Read online

It is shown that when using eddy current thickness meter with superimposed transducer the maximal thickness of the conductive sheets or conductive surface layers of a two-layer wares, which may be controlled with selected frequency of excitation current of the transducer, can be estimated based on the magnitude of the penetration depth of a plane electromagnetic wave in the half-space, the specific electrical conductivity and the relative magnetic permeability of which is equal to the values of these parameters in a controlled surface layer or sheet of two-layer ware.

Keywords