Sensors (Jan 2024)
Real World Interstitial Glucose Profiles of a Large Cohort of Physically Active Men and Women
Abstract
The use of continuous glucose monitors (CGMs) in individuals living without diabetes is increasing. The purpose of this study was to profile various CGM metrics around nutritional intake, sleep and exercise in a large cohort of physically active men and women living without any known metabolic disease diagnosis to better understand the normative glycemic response to these common stimuli. A total of 12,504 physically active adults (age 40 ± 11 years, BMI 23.8 ± 3.6 kg/m2; 23% self-identified as women) wore a real-time CGM (Abbott Libre Sense Sport Glucose Biosensor, Abbott, USA) and used a smartphone application (Supersapiens Inc., Atlanta, GA, USA) to log meals, sleep and exercise activities. A total of >1 M exercise events and 274,344 meal events were analyzed. A majority of participants (85%) presented an overall (24 h) average glucose profile between 90 and 110 mg/dL, with the highest glucose levels associated with meals and exercise and the lowest glucose levels associated with sleep. Men had higher mean 24 h glucose levels than women (24 h—men: 100 ± 11 mg/dL, women: 96 ± 10 mg/dL). During exercise, the % time above >140 mg/dL was 10.3 ± 16.7%, while the % time p < 0.001). Overall, we see small differences in glucose trends during activity and sleep in females as compared to males and higher levels of both TAR and TBR when these active individuals are undertaking or competing in endurance exercise training and/or competitive events.
Keywords