Results in Engineering (Sep 2024)
Inverse-time protection method of pumped-storage unit vibration
Abstract
Vibration protection is a reliable mean for safe operation of rotating machinery. In recent years, vibration protection of pumped storage unit gets more and more complicated, resulting in an increasing risk of vibration protection system failure. Focusing on vibration characteristics of pumped-storage units, the inverse-time vibration protection method for of pumped-storage unit vibration was proposed based on material fatigue damage curve and linear damage accumulation theory. Difficulties of determining damage level were provided on applying damage accumulation method to vibration protection. Simplified inverse-time protection method for vibration of pumped-storage unit was proposed, and research showed that the inverse-time vibration protection threshold should be set according to vibration accumulation that avoids all unit transient processes, the reliability coefficient can be determined from 1.5 to 2.0, the refresh periods of unit vibration characteristic values do not affect the cumulative calculation results, and the inverse-time vibration protection has characteristic of self-returning. The vibration protection method based on inverse-time has the advantages of reliable principle, simple logic, and easy implementation. It has the characteristics of reliability, selectivity, sensitivity, and rapidity as relay protection in electric engineering. It solves the problem of dual parameter coordination in the traditional protection strategy with fixed threshold and fixed time delay. The method can be extended to the vibration protection of other types of rotating machinery.