Energies (Jun 2022)
A Visualized Experimental Study on the Influence of Reflux Hole on the Double Blades Self-Priming Pump Performance
Abstract
The self-priming pump is a kind of centrifugal pump product with self-priming function, and the structural parameters of its reflux hole determine the performance. In order to reveal the mechanism of the self-priming process, we summarized the influence of structure parameters of the reflux hole on the performance of the self-priming pump. In this study, the transparent experimental pump was designed and manufactured, and a visual test bench was built. The gas–liquid two-phase flow pattern during the self-priming process with different reflux hole structure parameters was captured by high-speed camera. Results showed that: (1) the reflux hole of the self-priming pump affected the self-priming performance of the pump by affecting the backflow rate of the gas and liquid phases during the self-priming process. (2) Due to the uneven distribution of liquid velocity in the pump, the position of reflux hole had an obvious impact on the duration of self-priming middle stage, and the shortest duration was 13 s when φ = +15° and the longest duration was 45 s when φ = −30°. (3) The diameter of reflux hole had a very significant impact on the duration of the self-priming middle stage, and the shortest duration was 17 s when d = 10 mm and the longest duration was 94 s when d = 0 mm.
Keywords