Single-Loop Triple-Diameter Pulsating Heat Pipes at Reduced Heat Input: A CFD Study on Inner Diameter Optimization
Abstract
The geometric configuration, particularly the inner tube diameter, plays a significant role in the thermal performance of pulsating heat pipes (PHPs). Previous experimental research has demonstrated that single-loop triple-diameter PHPs (TD-PHPs) outperform single-loop single-diameter PHPs (SD-PHPs) and dual-diameter PHPs (DD-PHPs) in terms of thermal performance under moderate heating input powers ranging from 25 W to 75 W. However, a reduction in heat input from 75 W to 25 W leads to a diminished impact of TD-PHPs on the thermal performance. Therefore, to improve the overall performance of TD-PHPs, this study used two-dimensional transient computational fluid dynamics simulations to identify the optimal inner tube diameters for TD-PHPs at a low heat input by evaluating the thermal resistance of five TD-PHPs with various inner diameters. The findings reveal that the TD-PHP configuration exhibits minimum thermal resistance, with inner diameters of 4.5 mm for the upper arch (the condenser section), 4.0 mm for the wide branch, and 2.5 mm for the narrow branch, primarily due to its full circulation flow pattern. Furthermore, the overall heat transfer performance of the optimal TD-PHP was compared with that of an SD-PHP at low heat inputs (10 and 18 W), indicating that although the optimal TD-PHP shows lower thermal resistance, it does not significantly affect the start-up time.
Keywords