AIP Advances (Nov 2017)

Analysis of the cool down related cavity performance of the European X-Ray Free Electron Laser vertical acceptance tests

  • M. Wenskat,
  • J. Schaffran

DOI
https://doi.org/10.1063/1.5004482
Journal volume & issue
Vol. 7, no. 11
pp. 115110 – 115110-8

Abstract

Read online

For the European X-Ray Free Electron Laser (XFEL) cavity production, the cold radio-frequency (RF) test of the cavities at 2K after delivery from the two vendors was the mandatory acceptance test. It has been previously reported, that the cool down dynamics of a cavity across Tc has a significant influence on the observed intrinsic quality factor Q0, which is a measure of the losses on the inner cavity surface. A total number of 367 cool downs is used to analyze this correlation and we show that such a correlation is not observed during the European XFEL cavity production.