Journal of NeuroEngineering and Rehabilitation (Sep 2024)
Reliability and usability of a novel inertial sensor-based system to test craniocervical flexion movement control
Abstract
Abstract Background Neck pain has a significant global impact, ranking as the fourth leading cause of disability. Recurrent neck pain often leads to impaired sensorimotor control, particularly in craniocervical flexion (CFF). The Craniocervical Flexion Test (CCFT) has been widely investigated to assess the performance of deep cervical flexor muscles. However, its use requires skilled assessors who need to subjectively detect compensations, progressive increases in range of motion (ROM) or excessive superficial flexor activation during the test. The aim of this study was to design and develop a novel Craniocervical Flexion Movement Control Test (CFMCT) based on inertial sensor technology and real-time computer feedback and to evaluate its safety and usability, as well as inter and intra-rater reliability in both healthy individuals and patients with neck pain. Methods We used inertial sensor technology associated with new software that provides real-time computer feedback to assess CCF movement control through two independent test protocols, the progressive consecutive stages protocol (including progressive incremental stages of ROM) and the random stages protocol (providing dynamic and less predictable movement patterns). We determined intra and inter-rater reliability and standard error of the measurement for both protocols. The participants rated their usability was analysed through the System Usability Scale (SUS) and possible secondary effects associated with the tests were registered. Results The progressive consecutive stages protocol and the random stages protocol were safe and easy to use (SUS scores of 82.00 ± 11.55 in the pain group and 79.56 ± 13.36 in the asymptomatic group). The progressive consecutive stages protocol demonstrated good inter-rater reliability (intraclass correlation coefficient [ICC] ≥ 0.75) and moderate to good intra-rater reliability (ICC 0.62–0.80). However, the random stages protocol exhibited lower intra-rater reliability, especially in the neck pain group, where the reliability values were poor in some cases (ICC 0.48–0.72). Conclusion The CFMCT (progressive consecutive stages protocol) is a promising instrument to evaluate CCF motor control in patients with chronic neck pain. It has potential for telehealth assessment and easy adherence for exercise prescription and seems to be a safe and usable tool for patients with pain and asymptomatic individuals. Its use as a test or for exercise needs to be further investigated to facilitate its transfer to clinical practice.