Sensors (Jul 2024)
Effortless Totem-Pole Converter Control Using a Power Factor Correction Peak Current-Mode Controller
Abstract
This paper expands a recently proposed peak current-mode (PCM) control method for a power factor correction (PFC) boost converter to include the totem-pole converter and solves the controller’s compatibility problem with the totem-pole converter by proposing three input current sensing methods. Using MATLAB/Simulink 2023b, simulation experiments on a 2 kW totem-pole converter utilizing the PFC PCM controller were carried out to assess the performance of the controller with the proposed sensing methods. The findings indicate that under steady-state conditions, all three proposed sensing methods performed input current shaping successfully and yielded nearly identical THD% of about 4.4% in the input current waveform. However, it is noteworthy that method 2, referred to as the memory method, exhibited a sluggish and less robust transient response in comparison to the swift and resilient responses observed with method 1 and method 3. Additionally, the third proposed method, which involves a single current sensor positioned across the input inductor, emerged as the optimal and cost-effective sensing solution. This method achieved the same desirable attributes of fast and robust control while utilizing only a single current sensor, a notable advantage over method 1, which employs two current sensors.