Frontiers in Cardiovascular Medicine (Mar 2022)

Patients With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

  • Yi Zhang,
  • Tian-Yuan Xiong,
  • Yi-Ming Li,
  • Yi-Jun Yao,
  • Jing-Jing He,
  • Hao-Ran Yang,
  • Zhong-Kai Zhu,
  • Fei Chen,
  • Yuanweixiang Ou,
  • Xi Wang,
  • Qi Liu,
  • Xi Li,
  • Yi-Jian Li,
  • Yan-Biao Liao,
  • Fang-Yang Huang,
  • Zhen-Gang Zhao,
  • Qiao Li,
  • Xin Wei,
  • Yong Peng,
  • Sen He,
  • Jia-Fu Wei,
  • Wen-Xia Zhou,
  • Ming-Xia Zheng,
  • Yun Bao,
  • Xuan Zhou,
  • Hong Tang,
  • Wei Meng,
  • Yuan Feng,
  • Mao Chen

DOI
https://doi.org/10.3389/fcvm.2022.794850
Journal volume & issue
Vol. 9

Abstract

Read online

ObjectiveWe sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized.MethodObservational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline.ResultsA total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75–0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV.ConclusionsDespite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

Keywords