Applied Sciences (Dec 2024)
Load Testing and Analysis of a Large Span Through Simply-Supported Steel Box Arch Bridge
Abstract
To evaluate the true load-bearing capacity and engineering reliability of a large span through a simply supported steel box arch bridge, a load test was conducted on the bridge. The example used in this test is the Jingchu Avenue Bridge located in Jingmen City, Hubei Province. Specifically, the static load test delineated six operational conditions, measuring parameters encompassing strain, hanger cable force, deflection, and potential cracks. The dynamic load test gauged the bridge’s dynamic response and various indicators, including pulse tests, vehicle tests, jump tests, and barrier-free vehicle tests. The findings indicated that the maximum measured strain values during the static load test surpassed the calculated values; nonetheless, the verification factors and relative residual strains adhered to the code requirements, and no cracks were detected. The dynamic load test unveiled that the measured frequency values exceeded the theoretical ones, the damping ratios were within the normal range, and the measured impact coefficients were lower than the values stipulated in the code, all of which were in conformance with the code requirements. The data obtained from this experiment can be utilized to refine the long-term maintenance plan for the bridge, especially as it holds considerable value for structural health monitoring and aging assessment.
Keywords