Medicina (May 2023)

An Analysis of Early Results after Valve Replacement in Isolated Aortic Valve Stenosis by Using Sutureless vs. Stented Bioprostheses: A Single-Center Middle-Income Country Experience

  • Marko Kaitovic,
  • Slobodan Micovic,
  • Ivan Nesic,
  • Tatjana Raickovic,
  • Jelena Dotlic,
  • Ivan Stojanovic,
  • Tatjana Gazibara

DOI
https://doi.org/10.3390/medicina59061032
Journal volume & issue
Vol. 59, no. 6
p. 1032

Abstract

Read online

Background and Objectives: There is a lack of data about the survival of patients after the implantation of sutureless relative to stented bioprostheses in middle-income settings. The objective of this study was to compare the survival of people with isolated severe aortic stenosis after the implantation of sutureless and stented bioprostheses in a tertiary referral center in Serbia. Materials and Methods: This retrospective cohort study included all people treated for isolated severe aortic stenosis with sutureless and stented bioprostheses from 1 January 2018 to 1 July 2021 at the Institute for Cardiovascular Diseases “Dedinje”. Demographic, clinical, perioperative and postoperative data were extracted from the medical records. The follow-up lasted for a median of 2 years. Results: The study sample comprised a total of 238 people with a stented (conventional) bioprosthesis and 101 people with a sutureless bioprosthesis (Perceval). Over the follow-up, 13.9% of people who received the conventional and 10.9% of people who received the Perceval valve died (p = 0.400). No difference in the overall survival was observed (p = 0.797). The multivariate Cox proportional hazard model suggested that being older, having a higher preoperative EuroScore II, having a stroke over the follow-up period and having valve-related complications were independently associated with all-cause mortality over a median of 2 years after the bioprosthesis implantation. Conclusions: This research conducted in a middle-income country supports previous findings in high-income countries regarding the survival of people with sutureless and stented valves. Survival after bioprosthesis implantation should be monitored long-term to ensure optimum postoperative outcomes.

Keywords