Scientific Reports (Jul 2024)
Contrast efficacy of novel phase convertible nanodroplets for safe CEUS imaging
Abstract
Abstract Microbubble contrast agents in ultrasound/echocardiography are used to increase the echogenicity of the target tissues, thereby raising the contrast resolution of the resultant image. Recently, the trend has shifted toward the development of phase-convertible nanodroplets as ultrasound contrast agents due to their promising theragnostic potential by switching capability at the active site. Herein, we fabricated pre-PGS- perfluoropentane phase convertible nanodroplets and checked their in vitro and in vivo enhancement and safety profile. For this, we performed experiments on 20 male Wistar rats and 2 dogs. Biochemical assays of both rats and dogs included complete blood profiles, liver function tests, and renal function tests. For rat vitals, monitoring and histopathological analysis were also performed. Converted nanodroplets showed excellent contrast enhancement, better than Sonovue upon in vitro testing, with an enhancement time of up to 14 min. In vivo, experiments showed comparable opacification of the ventricles of both rats and dogs. All biochemical assays remained within the normal range during the study period. The histopathological analysis did not show any signs of drug-induced toxicity, showing the safety of these nanodroplets. Pre-PGS-PFP nanodroplets hold great potential for use in echocardiography and abdominal imaging in both human and veterinary applications after clinical trials.
Keywords