Advances in Bridge Engineering (Feb 2024)

Fatigue performance of ECC link slab incorporated full RC girder joint-free bridges

  • Khandaker M. Anwar Hossain,
  • Katie Chu,
  • Mohamed Lachemi

DOI
https://doi.org/10.1186/s43251-024-00114-8
Journal volume & issue
Vol. 5, no. 1
pp. 1 – 17

Abstract

Read online

Abstract The use of link slab (LS) made of Engineered Cementitious Composite (ECC) in the construction of joint-free bridge deck can meet structural performance requirements and enhance durability to minimize life cycle costs. Studies documented in the literature to date have been limited to composite steel-concrete I-deck girder bridges despite their commonly used reinforced concrete (RC) girder counterparts in construction. This paper deals with two span full RC deck girder joint-free bridges with ECC link slab (ECC-LS) constructed and tested under static and fatigue loading up to 1,000,000 cycles at 4 Hz subjected to mean stress level of 40% of girder ultimate load, followed by post-fatigue static loading to failure. Residual load, deflection, moment, rotation, stiffness, and energy absorbing capacity of fatigued bridge specimens are compared with its virgin (non-fatigued) counterparts to assess structural performance. Experimental moment capacities are compared with those obtained from existing analytical equations. The comparative performance of joint-fee bridge with RC deck girder is compared with its composite steel-concrete I-girder counterpart to assess its feasibility of construction.

Keywords