Arthroscopy, Sports Medicine, and Rehabilitation (Feb 2024)

Cells Remain Viable When Collected With an In-Line-Suction Tissue Collector From Byproducts of Anterior Cruciate Ligament Reconstruction Surgery

  • Adam W. Anz, M.D.,
  • Joshua J. Cook, M.S., A.C.R.P.-P.M., C.C.R.C.,
  • Eric A. Branch, M.D.,
  • Charlkesha A. Rahming, M.S.,
  • Roger V. Ostrander, III, M.D.,
  • Steve E. Jordan, M.D.

Journal volume & issue
Vol. 6, no. 1
p. 100860

Abstract

Read online

Purpose: To investigate the viability of cells collected with an in-line-suction autologous tissue collector from the tissue byproducts of arthroscopic anterior cruciate ligament (ACL) reconstruction, to characterize cells from different tissue types, and to identify mesenchymal stem cells. Methods: Patients aged 14 to 50 years with ACL injuries requiring arthroscopic reconstruction surgery were offered enrollment and screened for participation. In total, 12 patients were enrolled in the descriptive laboratory study. Arthroscopic byproduct tissue was collected with an in-line-suction autologous tissue collector from 4 intraoperative collection sites for each patient: ACL stump, ACL fat pad, notchplasty debris, and tunnel drilling debris. All tissue samples were digested using collagenase, and the derived cellular populations were analyzed in vitro, characterizing cellular viability, proliferative potential, qualitative multipotent differentiation capacity, and cell-surface marker presence. Results: An equivalent mass of arthroscopic byproduct tissue was taken from each of the 4 intraoperative collection sites (1.12-1.61 g, P = .433), which all showed an average viability of at least 99.95% and high average total nucleated cells (≥1.37 × 107 cells/mL). No significant differences in collected mass (P = .433), cellular viability (P = .880), or total nucleated cells (P = .692) were observed between the 4 byproduct tissues. The byproduct tissues did exhibit significant differences in monocyte (P = .037) and red blood cell (P = .038) concentrations, specifically with greater values present in the ACL stump tissue. Cells from all byproduct tissues adhered to plastic cell culture flasks. Significant differences were found between colony-forming unit fibroblast counts of the 4 byproduct tissues when plated at 106 (P = .003) and 103 (P = .016) cells as the initial seeding density. There was a significant relationship found between both the starting concentration (χ2 = 32.7, P 75%), and did not express CD45 (<10%). There were no statistically significant differences in cell-surface antigens between the four byproduct tissues. Conclusions: This descriptive laboratory study demonstrated that cells derived from arthroscopic byproduct tissues of ACL reconstruction remain viable when collected with an in-line-suction autologous tissue collector and these cells meet the ISCT criteria to qualify as mesenchymal stem cells. Clinical Relevance: It is known that viable mesenchymal stem cells reside in byproduct tissue of anterior cruciate ligament reconstruction surgery (ACLR). Practical methods to harvest these cells at the point of care require further development. This study validates the use of an in-line-suction autologous tissue collector for the harvest of viable mesenchymal stem cells after ACLR.