Energy Reports (Nov 2022)

Research on dead-time compensation of common DC bus OW-PMSM based on 120°decoupling modulation

  • Shirui Xie,
  • Yinhang Ning,
  • Zhaoyuan Zhang,
  • Haihong Qin,
  • Xinpeng Feng,
  • Chaohui Zhao

Journal volume & issue
Vol. 8
pp. 486 – 493

Abstract

Read online

To suppress the switching dead-band in the Open-End Winding Permanent Magnet Synchronous Machine with Common DC bus (OW-PMSM-CDCB) drive system, the dual-inverter switch dead-band generates zero-sequence voltage and current during 120°decoupling modulation. The generation mechanism of dead-band voltage is analyzed with the help of Matlab/Simulink and a method to compensate for the zero-sequence voltage resulting from the dead-band of dual-inverter switches is discussed in this study. With the help of current polarity detection, the zero-sequence voltage resulting from the dead-band of the switch is offset by solving the dead-band voltage compensation amount, and an OW-PMSM-CDCB drive system experimental platform is built for experimental verification. Simulation and experimental show that the proposed compensation method can effectively suppress the zero-sequence current of OW-PMSM-CDCB.

Keywords