Atmosphere (Oct 2021)

Exposure to Particles and Gases in a Shopping Mall: Spatial Heterogeneity and Outdoor Infiltration

  • Alison Tan-Yui Li,
  • Wen-Wei Che,
  • Yu-Shan Song,
  • Jimmy Chun-Kung Tong,
  • Alexis Kai-Hon Lau

DOI
https://doi.org/10.3390/atmos12101313
Journal volume & issue
Vol. 12, no. 10
p. 1313

Abstract

Read online

Shopping malls in Hong Kong are usually located near major roads. Indoor air quality (IAQ) in these buildings is subject to infiltration of outdoor traffic-related pollutants, such as PM10, PM2.5, CO, and NO2. Furthermore, the existence of indoor sources and building geometry added to the complexity of variations in IAQ. To understand outdoor infiltration and spatial heterogeneity of these pollutants, we conducted fixed and cruise indoor sampling, together with simultaneous outdoor measurements, in a typical mall in Hong Kong. The cruise sampling was conducted indoors on a predesigned route and repeated 15 times. Outdoor infiltration was quantified based on regression analysis between indoor and outdoor sampling. Results showed that 75% of PM2.5, 53% of PM10, and 59% of NO2 were infiltrated into the mall during opening hours. Elevated PM2.5 and CO were observed during the dinner period, suggesting an impact from cooking. Substantial spatial variations were observed for PM10, PM2.5, and NO2, particularly at locations near entrances and restaurants. Measures are needed to reduce pollution intrusion from building openings and cooking-related sources to improve air quality in the selected mall. Fixed and cruise sampling methods used in this study provide insights on sensor deployment for future air quality monitoring in buildings.