BMC Ophthalmology (Aug 2024)

Comparison of visual efficacy and patient’s satisfaction between two toric IOLs, enhanced for intermediate vision and monofocal

  • Ho Sik Hwang,
  • Dohyeon An,
  • Hyun Seung Kim,
  • Eun Chul Kim

DOI
https://doi.org/10.1186/s12886-024-03589-1
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background To compare the visual efficacy and patient satisfaction between 2 toric IOLs (TIOL), enhanced for intermediate vision or monofocal. Methods A retrospective chart review was performed of 100 eyes from 68 astigmatic patients who underwent cataract surgery with implantation of a Tecnis Eyhance Toric II IOL (Johnson & Johnson Vision, Irvine, CA, USA) (Group 1, 50 eyes) or Tecnis TIOL (Group 2, 50 eyes). The uncorrected distant (UDVA), intermediate (UIVA), and near (UNVA) visual acuities; residual refractive astigmatism; defocus curve; and IOL axis rotation were evaluated at 1 week, 1 month, 2 months, and 3 months postoperatively. Results The postoperative UDVA and UNVA refractive astigmatism values of the two groups were better than the preoperative measurements (P 0.05). The postoperative UIVA of group 1 (0.18 ± 0.15 logMAR) was significantly better than that of group 2 (0.30 ± 0.25) (P < 0.05). The mean postoperative IOL rotation of group 1 (2.51 ± 0.79°) was lower than that of group 2 (3.02 ± 0.84°) (P < 0.05). Overall satisfaction of group 1 (1.27 ± 0.47) was better than that of group 2 (2.02 ± 0.53) (P < 0.05). Conclusions The Tecnis Eyhance Toric II IOL demonstrated less postoperative IOL rotation and excellent uncorrected intermediate vision compared with the Tecnis TIOL. Near visual acuity and overall satisfaction with the Tecnis Eyhance Toric II IOL were also higher than those with the Tecnis TIOL.

Keywords