BioTechniques (Sep 2015)

Two-step protocol for preparing adherent cells for high-throughput flow cytometry

  • Mandeep Kaur,
  • Luke Esau

DOI
https://doi.org/10.2144/000114325
Journal volume & issue
Vol. 59, no. 3
pp. 119 – 126

Abstract

Read online

We have developed a simple, cost-effective, and labor-efficient two-step protocol for preparing adherent cells for high-throughput flow cytometry. Adherent cells were grown on microplates, detached with 2.9 mM EDTA (pH 6.14) added directly to wells containing cell culture medium, stained, and then analyzed on a flow cytometer. This protocol bypasses washing, centrifugation, and transfer between plates, reducing the cell loss that occurs in standard multistep protocols. The method has been validated using six adherent cell lines, four commercially available dyes, and two antibodies; the results have been confirmed using two different flow cytometry (FC) instruments. Our approach has been used for estimating apoptosis, mitochondrial membrane potential, reactive oxygen species, and autophagy in response to exposure to pure compounds as well as plant and bacterial extracts.

Keywords