Scientific Reports (May 2023)

Establishment and application of suspension static method in blood group screening of automated blood group analyzer

  • Min Huang,
  • Chengping Ma,
  • Yan Li,
  • Ruiping Dong,
  • Rongrong Pang,
  • Shuizhen Huang,
  • Qiang Fu,
  • Libo Zhang

DOI
https://doi.org/10.1038/s41598-023-34495-z
Journal volume & issue
Vol. 13, no. 1
pp. 1 – 9

Abstract

Read online

Abstract The accuracy of blood group identification is the basis of blood transfusion safety. In order to increase the detection rate of weak agglutination, unexpected antibodies (UAb) and blood subtypes for pre-transfusion testing, the blood group screening process of automated blood group analyzer (ABGA) is ameliorated by introducing one static step and establishing a suspension static method (SSM). One static step was introduced in the blood group screening process of ABGA and three static time conditions were designed: 300 s, 400 s and 500 s, from which the optimal static time was selected and SSM was established; By comparing the detection of weak agglutination and UAb before and after the application of SSM, the feasibility and effect of suspension static method were verified and evaluated. The last two steps of the automatic blood group screening process were replaced with static, light centrifugation and imaging. The optimal static time parameter was selected as 400 s and SSM was established; After the application of SSM, it was verified that: (1) The detection level of weak antibodies (anti-A and anti-B) and weak antigens (weak D phenotype) could be improved by SSM, including antibodies in plasma of known type O samples with 0, 2, 4, 8, 16 and 32 times serial dilutions(simulating weak anti-A and weak anti-B), weak antibodies (anti-B) in plasma of one normal A-type sample and weak antigens on red blood cells (RBC) of 5 weak D phenotype samples (weak D antigen); (2) Three blood donor samples (type A, O and B) with known UAb were detected by SSM. The results showed that SSM could detect both weak antibodies (anti-A and anti-B) and UAb; (3) SSM was applied to detect the samples of 3 A2B and 3 subtype B blood donors and the blood subtypes could be clearly detected; (4) The number of screening samples was 95,314 and 106,814 before SSM (2018) and after (2020) the application of SSM and the positive rate of UAb (63/95,314 and 187/106,814) increased after SSM, discrepancy of which was statistically significant (χ 2 = 48.42, P < 0.01). The above results demonstrate that SSM of ABGA is conducive to the detection of weak agglutination, UAb and blood subtypes in blood samples, which can improve the sensitivity of blood group detection and ensure the safety of clinical blood transfusion to a certain extent.