Orthopaedic Surgery (Apr 2022)

Do Radiographic Results of Transforaminal Lumbar Interbody Fusion Vary with Cage Position in Patients with Degenerative Lumbar Diseases?

  • Qing Ding,
  • Xiangyu Tang,
  • Ruizhuo Zhang,
  • Hua Wu,
  • Chaoxu Liu

DOI
https://doi.org/10.1111/os.13224
Journal volume & issue
Vol. 14, no. 4
pp. 730 – 741

Abstract

Read online

Objective To investigate whether the radiographic results are affected by cage position in single‐level transforaminal lumbar interbody fusion (TLIF). Method Between January 2016 and June 2018, 130 patients (62 males and 68 females, average age: 55.28 ± 10.11 years) who underwent single‐level TLIF were analyzed retrospectively. Standing lateral radiographs of the lumbar spine were collected and evaluated preoperatively, postoperatively, and at the time of last follow‐up. Cage position in the fused segment was recorded using a central point ratio (CPR), which indicated the cage position. CPR is calculated by dividing the distance between the cage center point and the posterior extent of the superior endplate of the inferior vertebra by the length of the superior endplate of the inferior vertebra. Based on cage positions, the patients were divided into three groups: Anterior Group (n = 38); Middle Group (n = 68); and Posterior Group (n = 24). Segmental lumbar lordosis (SLL), foraminal height (FH), posterior disc height (PDH), and anterior disc height (ADH) were evaluated. A subanalysis was also performed on cage height within each group. Results The average follow‐up time of the patients was 35.20 ± 4.43 months. The mean values of CPR in Anterior Group, Middle Group, and Posterior Group were 0.64, 0.51, and 0.37, respectively. The FH, PDH, and ADH were significantly increased after TLIF in all groups (P 0.05). The significant correlations in surgery were: CPR and ΔSLL (r = 0.584, P < 0.001), CPR and ΔFH (r = −0.411, P < 0.001), and CPR and ΔPDH (r = −0.457, P < 0.001). However, ADH had a positive correlation with cage height when the cage was located in anterior and middle of the endplate. Moreover, cage height had a positive correlation with SLL when the cage was located anteriorly and had a negative correlation with SLL when the cage was located posteriorly. FH and PDH both had a positive correlation with cage height in any cage position. Conclusion The cage located in different positions has different effects on radiographic results in single‐level TLIF. A thicker cage located anteriorly will gain maximum SLL and avoid the reduction of FH and PDH.

Keywords