SICE Journal of Control, Measurement, and System Integration (Nov 2020)
Bandwidth Maximization of Disturbance Observer Based on Experimental Frequency Response Data
Abstract
A disturbance observer (DOB) has been widely employed in industrial field due to its simplicity and effectiveness in disturbance rejection. This paper focuses on systematic bandwidth-maximized DOB design by frequency response data-based convex optimization. The transformation process from original non-convex optimization to convex optimization has been formulated. Simulation results have verified the feasibility and generality of the proposal and shown that the designed DOB is able to achieve good disturbance rejection performance.
Keywords