BMC Oral Health (Sep 2024)

Surface topography changes and wear resistance of different non-metallic telescopic crown attachment materials in implant retained overdenture (prospective comparative in vitro study)

  • Sherif M. Abdel Hamid,
  • Rim A. Selima,
  • Mohamed Z. Basiony

DOI
https://doi.org/10.1186/s12903-024-04839-w
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 11

Abstract

Read online

Abstract Background The purpose of this study was to evaluate the effect of using different types of metallic and non-metallic telescopic crown attachment materials on wear resistance and surface tomography changes in implant-retained mandibular overdentures. Materials and methods Completely edentulous mandibular epoxy models were fabricated, in which two implants were placed in the canine region and retained to the implants with three different material combinations used for the construction of telescopic attachments. Thirty-three identical mandibular overdentures were fabricated using the conventional standardized technique. The study groups were divided into three categories according to the material used for the construction of the secondary copings. The primary copings in all the study groups were constructed of PEEK, while the secondary coping in group I was PEEK, group II was ZrO2 and CoCr for group III. Primary copings were cemented on a ready-made abutment. Secondary copings were placed over the primary copings in the desired path of insertion, then picked up into the intaglio surface of the overdentures. A cyclic loading machine was used to apply repeated insertion-removal cycles simulating nearly 10 years of clinical use. Stereomicroscope with a built-in camera was used to monitor the reduction in width of the primary copings to evaluate the wear resistance of each material combination. Results There was highly statistically significant difference between the study groups after the application of 1.000, 5.000 and 10.000 cycles. The highest level of wear resistance was recorded for the PEEK/PEEK combination, whereas PEEK/ZrO2 and PEEK/CoCr showed no significant differences. Conclusions Implant retained overdenture with PEEK-PEEK telescopic crown attachment is associated with the highest wear resistance among all the study groups. PEEK-PEEK combination may be the treatment of choice for fabrication of telescopic attachment in implant retained overdenture as it provides better resistance to wear. It offers the advantages for geriatric patients as it decreases the possibility for repeated repair and replacement of attachment, increase long-term patient satisfaction and shelf life of prosthesis.

Keywords