Machines (Aug 2024)
Research on Suppressing Commutation Torque Ripple of BLDCM Based on Zeta Converter
Abstract
Torque ripple in a brushless DC motor (BLDCM) seriously restricts its application in high-performance fields. This paper proposes a commutation torque ripple suppression strategy based on a Zeta converter. The expected output voltage of a Zeta converter that suppresses the commutation torque ripple is obtained, according to the effect of the duty ratio of the Zeta converter on the turn-off phase freewheeling duration and the turn-on phase rising duration, during commutation. Based on the analysis of the dynamic response of the Zeta converter, the Zeta converter is adjusted to ensure that the Zeta converter reaches stability in sufficient time. During the commutation, the output voltage of the Zeta converter is connected to the main circuit to reduce the torque ripple during commutation, and the expected regulated duty cycle of the Zeta converter during the next commutation is calculated to adjust the output voltage of the Zeta converter. Based on this analysis, the experimental results verify the effectiveness of the proposed method.
Keywords