Journal of Dental Sciences (Dec 2016)

Ultrasonic cleaning reduces the residual monomer in acrylic resins

  • Taksid Charasseangpaisarn,
  • Chairat Wiwatwarrapan,
  • Nonthida Leklerssiriwong

DOI
https://doi.org/10.1016/j.jds.2016.07.003
Journal volume & issue
Vol. 11, no. 4
pp. 443 – 448

Abstract

Read online

Background/purpose: The residual monomer remaining in acrylic resin can cause an allergic reaction and is toxic to oral soft tissue. This study determined the effect of the duration of ultrasonic cleaning on the amount of residual methyl methacrylate monomer in one heat-polymerized acrylic resin, Meliodent, and three autopolymerized acrylic resins, Unifast Trad Ivory, Unifast Trad Pink, and Unifast III. Materials and methods: Thirty-six disc-shaped specimens of each brand were prepared and randomly divided into six groups: control (no treatment), positive control, and ultrasonic treatment in 50°C water for 3 minutes, 5 minutes, 10 minutes, or 15 minutes. The residual monomer was extracted and analyzed using high performance liquid chromatography. Results: There were no significant differences in the residual monomer amount in the Meliodent groups. The amounts of residual monomer in the autopolymerized acrylic resin positive control group and ultrasonic treatment groups were significantly lower than those of the control group for the Unifast Trad Ivory, Unifast Trad Pink, and Unifast III groups (P0.05). Conclusion: Ultrasonic treatment with 50°C water for 3–5 minutes for autopolymerized resin and 3 minutes for heat-polymerized acrylic resin reduced the amount of residual monomer similarly to previously recommended methods, using shorter treatment times.

Keywords