Applied Sciences (May 2023)

Hydraulic Prototype Observation Tests on Reconstructed Energy Dissipation Facilities

  • Hai Wei,
  • Kaiyun Tao,
  • Yongqin Luo,
  • Bingyue Song,
  • Mingming Wang,
  • Juncai Xu

DOI
https://doi.org/10.3390/app13106216
Journal volume & issue
Vol. 13, no. 10
p. 6216

Abstract

Read online

In order to assess the effectiveness of reconstructed energy dissipation facilities (EDFs) in open channels at hydropower stations, hydraulic prototype observation (HPO) tests are conducted to investigate the characteristics of discharge flow and the dynamic response of hydraulic structures during sluice opening periods. While hydraulic model tests (HMTs) are commonly utilized in laboratory settings to study these characteristics, experimental conditions cannot fully replicate the real-world operations of such structures. HPO tests are employed to examine flow patterns, free water surface fluctuations, and pulsating pressure changes in open channels under varying flood discharge conditions (FDCs). Flow patterns in open channels are recorded via video; free water surface fluctuations are measured using total-station and laser rangefinder instruments; and pulsating pressure is monitored with pressure sensors and data collection systems. Flow pattern observations concentrate on addressing adverse water flow phenomena, such as turbulence, surging, and backflow. The examination of free water surface fluctuations aims to verify whether the height of the guide wall along the open channel fulfills the necessary requirements and assess the effectiveness of energy dissipation of the EDF. To comprehend the variations in pulsating pressure within the continuous sill and the base slab, nine measurement points were established across three sections perpendicular to the continuous sill’s axis on three distinct elevation levels. Additionally, three measurement points were positioned on the reinforced base slab along the open channel’s axis. The findings indicate that the impact on the continuous sill caused by discharging water is more severe when the discharge rate of a single sluice gate reaches 500 m3/s than in other FDCs. To ensure the safe operation of open channels during flood discharge, the discharge rate for each sluice gate should be reduced to 250 m3/s. The dominant pulsation induced by discharge flow falls within the low-frequency range, resulting in minimal adverse effects on the stilling basin and guide wall. The flow pattern within the stilling basin remains stable under various FDCs, with no significant adverse hydraulic phenomena observed. Parameters, including free water surface fluctuations and pulsating pressure variations, lie within acceptable ranges. These observations suggest that the arrangement of the reconstructed energy dissipation facilities is generally effective following technical reconstruction.

Keywords