Journal of Biomedical Physics and Engineering (Sep 2017)

Modification of Source Strength in LowDose-Rate Lung Brachytherapy with125I and 103Pd Seeds

  • Rezaei H.,
  • Mostaghimi H.,
  • Mehdizadeh A. R.

Journal volume & issue
Vol. 7, no. 3
pp. 191 – 204

Abstract

Read online

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. Objective: The present study aims to modify source strength for different configurations of 125I and 103Pd seeds used in lung permanent implant brachytherapy. Methods: Different arrays of 125I and 103Pd seeds were simulated by MCNPX code in protocol-based water vs. actual 3D lung environments. Absorbed dose was, then, scored in both mediums. Dose differences between both environments were calculated and source strength was modified for the prescription point. In addition, lung-towater absorbed dose ratio was obtained and presented by precise equations. Results: Due to significant differences in prescription dose, source strength was modified 16%-19% and 37%-43% for different configurations of 125I and 103Pd seeds, respectively. In addition, depth-dependent dose differences were observed between the actual lung and protocol-based water mediums (dose difference as a function of depth). Conclusion: Modification of source strength is essential for different arrangements of 125I and 103Pd seeds in lung implantation. Modified source strength and presented equations are recommended to be considered in future studies based on lung brachytherapy.

Keywords