JA Clinical Reports (Oct 2022)
The effects of chest drainage on pressure-controlled ventilation
Abstract
Abstract Background The use of pressure-controlled ventilation (PCV) for anesthesia management is becoming more commonly used. Chest drainage is commonly performed after thoracic surgery, and the negative pressure it generates might affect the transpulmonary pressure (TPP). In the present study, we investigated how chest drainage could affect ventilating conditions during PCV. Methods We created a hand-made simple thoracic and lung model, which was connected to an anesthesia machine. The tidal volume (TV) was measured with positive end-expiratory pressure (PEEP) 0 and no chest drainage (baseline), followed by 10 cmH2O PEEP/no drainage, 10 cmH2O PEEP/drainage with − 10 cmH2O and 10 cmH2O PEEP/drainage with − 20 cmH2O. Finally, TV with 20 cmH2O and 30 cmH2O PEEP/no drainage was measured. Driving (inspiratory) pressure was maintained at 20 cmH2O during the whole experiment. Results TV was significantly increased by applying 10 cmH2O PEEP compared with baseline, further increased by applying − 10 cmH2O by drainage, similar to the value with PEEP 20 cmH2O with no drainage (end-tidal TPP of 20 cmH2O for both). TV decreased to < 50% of the baseline by applying 10 cmH2O PEEP with − 20 cmH2O by drainage, which was similar to that with 30 cmH2O PEEP with no drainage (end-tidal TPP of 30 cmH2O for both). Conclusions TV was maintained at similar levels with the same TPP, regardless of PEEP or negative pressure by chest drainage change, suggesting that negative intrapleural pressure by the chest tube drainage system might mimic PEEP from the point of TV.
Keywords