Journal of Applied Oral Science (Feb 2010)

Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study

  • Luciana Borges Retamoso,
  • Niége Michelle Lazzari Onofre,
  • Luciane Hann,
  • Ernani Menezes Marchioro

DOI
https://doi.org/10.1590/S1678-77572010000100012
Journal volume & issue
Vol. 18, no. 1
pp. 68 – 74

Abstract

Read online

OBJECTIVES: To determine the influence of the light curing units on the shear bond strength of orthodontic brackets. MATERIAL AND METHODS: Seventy-two premolars were divided into six groups (n=12): Group I: brackets bonded with Transbond and polymerization with halogen light; Group II: Transbond and LED; Group III: Fuji Ortho and halogen light; Group IV: Fuji Ortho and LED; Group V: Fuji Ortho, without acid and halogen light; Group VI: Fuji Ortho, without acid and LED. The groups were tested to shear strength in a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. RESULTS: The composite resin presented higher shear bond strength than the resin-modified glass ionomer cement (p0.05). CONCLUSION: The shear bond strength was influenced by the material but not by the light-curing unit. The use of LED reduced the experimental time by approximately 60%, with the same curing efficiency.

Keywords