Clinical Ophthalmology (Dec 2023)

Clinical Results and Factors Affecting Visual Function in Eyes Implanted with an Enhanced Monofocal Intraocular Lens

  • Negishi K,
  • Masui S,
  • Ayaki M,
  • Torii H,
  • Yotsukura E,
  • Nishi Y

Journal volume & issue
Vol. Volume 17
pp. 3965 – 3973

Abstract

Read online

Kazuno Negishi,1 Sachiko Masui,1 Masahiko Ayaki,1,2 Hidemasa Torii,1 Erisa Yotsukura,1 Yasuyo Nishi1 1Department of Ophthalmology, Keio University School of Medicine, Shinjuku‑Ku, Tokyo, Japan; 2Otake Clinic Moon View Eye Center, Yamato-City, Kanagawa, JapanCorrespondence: Kazuno Negishi, Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku‑Ku, Tokyo, 160‑8582, Japan, Tel +81-3-3353-1211, Fax +81-3-3359-8302, Email [email protected]: To compare the clinical results achieved with the enhanced monofocal intraocular lenses (IOLs) with those of the monofocal IOL and investigate factors affecting the distance, intermediate, and near vision.Patients and Methods: Patients were included who underwent bilateral consecutive cataract surgeries using the same IOLs with follow-up to 1 month postoperatively. Refractions, monocular UDVA and CDVA, and binocular distance-corrected functional visual acuity at 5 meters (BDCFVA), at 66 centimeters (BDCIFVA) and at 40 centimeters (DCNVA) were assessed. Multiple regression analysis was used to assess the factors affecting binocular BDCFVA, BDCIFVA, and BDCNFVA. Subjective symptoms were assessed using the Near Activity Visual Questionnaire (NAVQ) and visual analogue scale (VAS).Results: Sixty patients (120 eyes) implanted with the Tecnis Eyhance IOL (30 patients, 60 eyes) or the Tecnis monofocal IOL (30 patients, 60 eyes) were included. The Tecnis Eyhance IOL provided significantly better binocular BDCIFVA than the Tecnis monofocal IOL in patients under 70 years of age. Multiple regression analysis showed that age was the only factor affecting distance and intermediate visual function in eyes with the Tecnis Eyhance IOL; gender, pupillary diameter, axial length, and average keratometry were not significant. There were no significant differences in subjective symptoms.Conclusion: The comprehensive cohort analysis did not confirm the advantage on the intermediate vision of the Tecnis Eyhance IOL. Younger age may be an important factor to benefit from the unique optical characteristics of this IOL.Keywords: presbyopia correcting intraocular lens, intermediate vision, functional visual acuity, age

Keywords