Fluids (Mar 2022)
High-Speed Imaging of Water Hammer Cavitation in Oil–Hydraulic Pipe Flow
Abstract
A pipe water hammer with column separation was studied in a range of flow rates (Re=465 to 2239) in a test rig with an acrylic glass observation section. Pressure transients were measured with piezoresistive pressure sensors, while the gas evaporation and condensation were captured by high-speed recording with a Photron SA-Z at a frame rate of 75,000 fps. Separation lengths were estimated by a threshold value in the images. The results did not show a sharp gas–oil interface but consisted of small, dispersed bubbles mixed with larger vapor structures, where the bubbles seemed to become smaller after each collapse. These findings differ from the transient cavitating characteristics commonly reported in nonhydraulic piping systems governed by different fluid properties and time scales. Good repeatability, both in terms of pressure transients and bubble distribution, was observed. The column separation was quantified as a metric of separation length, which was consistent between the tests. Combined with pressure measurements, these results may assist in obtaining a better understanding of the transient cavitation dynamics within oil–hydraulic systems as well as be used to improve modelling strategies towards more accurate cavitation erosion predictions.
Keywords