Arquivo Brasileiro de Medicina Veterinária e Zootecnia (Apr 2013)

Avaliação da qualidade microbiológica de bebida láctea e creme de leite UAT por ATP-Bioluminescência Evaluation of microbiological quality of UHT milk drink and UHT milk cream by ATP-Bioluminescence

  • A.F. Cunha,
  • A.D. Lage,
  • M.M. Pereira e Araújo,
  • R.D.P. Santos,
  • G.M. Resende,
  • M.M.O.P. Cerqueira

Journal volume & issue
Vol. 65, no. 2
pp. 595 – 600

Abstract

Read online

Embora métodos tradicionais sejam utilizados na avaliação microbiológica de produtos UAT, metodologias rápidas, baseadas em ATP-Bioluminescência, têm sido desenvolvidas. Os resultados da aplicação dessa técnica em 54 amostras de bebida láctea UAT achocolatada e 12 de creme de leite UAT foram comparados com os resultados de métodos microbiológicos, utilizando-se diferentes meios de cultura e tempos de incubação das referidas amostras. A técnica de ATP-Bioluminescência foi aplicada por meio do sistema MLS, e os resultados foram expressos em unidades relativas de luz (RLU). Em todos os tempos de incubação - 48, 72 e 168 horas - , as amostras apresentaram contagens baixas de microrganismos mesófilos e psicrotróficos aeróbios quando analisadas em meio PCA, BHI, PetrifilmTM AC e por ATP-Bioluminescência (Although traditional methods are used for the microbiological evaluation of UHT products, rapid methodologies based on ATP-Bioluminescence have been developed. The results of applying this technique in 54 samples of chocolate UHT milk drink and 12 of UHT milk cream were compared with the results of microbiological methods, using different culture media and incubation times for the referred samples. The ATP-Bioluminescence technique was applied through the MLS system and the results were expressed as relative light units (RLU). In all incubation times - 48, 72, and 168 hours - , the samples showed lower counts of mesophilic and psychrotrophic aerobic microorganisms when analyzed using PCA, BHI, PetrifilmTM AC and ATP-Bioluminescence (<150RLU), demonstrating the technique's high specificity. Only one sample of UHT milk cream showed a mesophilic aerobic count above the standard established by Brazilian legislation (<100CFU/mL) when analyzed in PCA (260 CFU/mL) and PetrifilmTM AC (108CFU/mL) at 168 hours. This high count of aerobic mesophilic microorganisms was also detected by the ATP-Bioluminescence (416 RLU) technique. The results of the ATP-Bioluminescence technique were equal to the results in PCA, BHI and PetrifilmTM AC.

Keywords