Open Engineering (Jul 2019)

Analysis of the influence of a stator type modification on the performance of a pump with a hole impeller

  • Chomiuk Bartłomiej,
  • Skrzypacz Janusz

DOI
https://doi.org/10.1515/eng-2019-0029
Journal volume & issue
Vol. 9, no. 1
pp. 218 – 228

Abstract

Read online

The article presents the results of numerical analyses and experimental research of the influence of various types of stators on a liquid flow through a centrifugal pump with a hole impeller. It is a continuation of authors research of cooperation pump stators with alternative types of impellers which work in ultra low specific speed. Hole impellers have become a significant alternative to classical ones in a range of extremely low specific speed nq<10. The aim of the research is to verify the quality as well as quantity of computer modeling results, and to estimate accuracy by examining the impact of a grid and a turbulence model with which the numerical simulations reflect the actual flow.Knowledge concerning construction of hydraulic elements of centrifugal pumps working in the range of parameters corresponding specific speed (nq<10) is insufficient. The outlet elements were tested in various configurations of constructional features. The complexity of the construction of the stator can significantly affect the manufacturing costs of pump unit.

Keywords