Energy Science & Engineering (Sep 2020)
On‐site detection of bypass circuit opening failure in photovoltaic array under power generation operation
Abstract
Abstract To ensure the long‐term reliability of photovoltaic systems (PVSs), periodical inspections are necessary. Despite the risk of severe temperature rise, bypass circuit open‐circuit (BPC‐OC) failure has attracted low research interest compared with other types of failure. This paper presents the pulsed light irradiation (PLI) method for robust BPC‐OC failure detection that eliminates the need to switch off the power generation operation of the PVS. The proposed method detects the BPC‐OC failure of the solar cell string by measuring the modulated current induced by local PLI. Electrical circuit simulations as well as indoor and outdoor experiments are performed to verify the performance of the proposed method. Results of the outdoor experiment show that the PLI method performs well in a real PVS under power generation operation. Finally, the advantages and disadvantages of the proposed method are summarized.