He huaxue yu fangshe huaxue (Aug 2023)
Separation of Trace Plutonium From Bulk Uranium Using Reillex-Reillex Anion Exchange Chromatography
Abstract
A highly efficient separation method for trace plutonium from high uranium plutonium ratio samples was established by combining two Reillex anion exchange chromatographic columns. The effects of resin type, wash condition, valence state adjustment on plutonium separation were investigated, and the conditions of separation process were determined. When the mass ratio of uranium to plutonium in the feed liquid is 106, after two-stage Reillex column separation, the average yield of plutonium is 99.35% and the decontamination factor of uranium is greater than 107. Using this process, high purity trace 239Pu is separated from irradiated uranium target, and the atomic ratio of (238U+238Pu)/239Pu is (3.60±1.15)×10-5(n=6).
Keywords