BMC Anesthesiology (Apr 2020)

Predictive factors for successful INTELLiVENT-ASV® use: a retrospective observational study

  • Shinshu Katayama,
  • Ken Tonai,
  • Jun Shima,
  • Kansuke Koyama,
  • Shin Nunomiya

DOI
https://doi.org/10.1186/s12871-020-01014-w
Journal volume & issue
Vol. 20, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background INTELLiVENT-ASV® (I-ASV) is a closed-loop ventilation mode that automatically controls the ventilation settings. Although a number of studies have reported the usefulness of I-ASV, the clinical situations in which it may be useful have not yet been clarified. We aimed to report our initial 3 years of experience using I-ASV, particularly the clinical conditions and the technical and organizational factors associated with its use. Furthermore, we evaluated the usefulness of I-ASV and determined the predictive factors for successful management with I-ASV. Methods This single-center, retrospective observational study included patients who were ventilated using the Hamilton G5® ventilator (Hamilton Medical AG, Rhäzüns, Switzerland) from January 2016 to December 2018. The patients were categorized into the “I-ASV success” group and “I-ASV failure” group (those receiving mechanical ventilation with I-ASV along with any other mode). Multivariate analysis was performed to identify factors associated with successful I-ASV management. Results Of the 189 patients, 135 (71.4%) were categorized into the I-ASV success group. In the I-ASV success group, the reasons for ICU admission included post-elective surgery (94.1%), post-emergent surgery (81.5%), and other medical reasons (55.6%). I-ASV failure was associated with a low P/F ratio (278 vs. 167, P = 0.0003) and high Acute Physiology and Chronic Health Evaluation (APACHE) II score (21 vs. 26, P < 0.0001). The main reasons for not using I-ASV included strong inspiratory effort and asynchrony. The APACHE II score was an independent predictive factor for successful management with I-ASV, with an odds ratio of 0.92 (95% confidential interval 0.87–0.96, P = 0.0006). The area under the receiver operating curve for the APACHE II score was 0.722 (cut-off: 24). Conclusions In this study, we found that 71.4% of the fully mechanically ventilated patients could be managed successfully with I-ASV. The APACHE II score was an independent factor that could help predict the successful management of I-ASV. To improve I-ASV management, it is necessary to focus on patient-ventilator interactions.

Keywords