Journal of Anesthesia, Analgesia and Critical Care (Jul 2024)

Sublingual sufentanil for patient-controlled analgesia during labor induction for pregnancy termination: an effective and well-tolerated approach

  • Giulia Fierro,
  • Barbara Milan,
  • Elena Buelli,
  • Dario Bugada,
  • Erika Casarotta,
  • Francesco Rizzo,
  • Laura Ongaro,
  • Paolo Gritti,
  • Fabio Previdi,
  • Ferdinando Luca Lorini

DOI
https://doi.org/10.1186/s44158-024-00177-z
Journal volume & issue
Vol. 4, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background Effective pain management during labor induction for pregnancy termination is essential. However, to date, no effective treatment has been identified. The primary aim of this study was to measure the analgesic efficacy of a sufentanil sublingual tablet system during pregnancy termination and patient satisfaction by comparing nulliparous and multiparous women. The secondary aims were to characterize the safety profile by reporting any side effects or adverse events and to determine the need for rescue therapy. Methods We conducted an observational, retrospective, single-center study involving 48 women. The data retrieved for analysis included the total and hourly doses of sublingual sufentanil, evaluations of pain management satisfaction using a 5-point rating scale (ranging from 1, indicating “not satisfied” to 5, denoting “completely satisfied”), occurrence of side effects and adverse events, and the rate of rescue analgesic use. Categorical and numerical variables were compared between the two groups, and a correlation analysis was performed. Results The median total dose of sufentanil required was 60 mcg. Nulliparous women required a higher dose of sufentanil compared with multiparous women (105 mcg vs. 45 mcg; P = 0.01). Additionally, they underwent a longer labor, indirectly measured by the time of device usage (625 min vs. 165 min; P = 0.05). Regarding satisfaction, 40 patients (83.4%) were satisfied or completely satisfied, whereas only 8 patients (16.6%) reported dissatisfaction. Multiparous women exhibited higher satisfaction levels than did nulliparous women (P = 0.03). No adverse events were reported, and the most common side effects were nausea and vomiting (31.2%). Four patients (12%) required acetaminophen due to insufficient analgesia, with only one patient necessitating a switch to intravenous morphine. Conclusions Sublingual sufentanil was effective in both nulliparous and multiparous women with minimal side effects. Therefore, sublingual sufentanil can be considered a valid strategy for analgesia during labor induction for pregnancy termination.

Keywords