Engineering Applications of Computational Fluid Mechanics (Dec 2023)

Photovoltaic-thermal system combined with wavy tubes, twisted tape inserts and a novel coolant fluid: energy and exergy analysis

  • Koorosh Khosravi,
  • Amir Hossein Eisapour,
  • Alireza Rahbari,
  • Jasim M. Mahdi,
  • Pouyan Talebizadehsardari,
  • Amir Keshmiri

DOI
https://doi.org/10.1080/19942060.2023.2208196
Journal volume & issue
Vol. 17, no. 1

Abstract

Read online

To create a highly efficient photovoltaic-thermal (PV-T) system and maximise the energy and exergy efficiency, this study aims to propose an innovative configuration of a PV-T system comprising wavy tubes with twisted-tape inserts. Following the validation of a numerical model, a parametric study has been conducted to assess the geometrical effects of twisted tape and wavy tubes, as well as the coolant fluid type and velocity, on the overall performance of a PV-T system, located in Shiraz, Iran. It is found that employing twisted tape improves the energy and exergy efficiency by approx. 6.3%. The best configuration yields 12.4% and 16.8% increase in energy and exergy efficiency compared to conventional PV systems. This is achieved at 15% volumetric concentration of microencapsulated phase change material slurry. The monthly variation of global horizontal irradiance in Shiraz highly affected the energy and exergy efficiency of PV-T, with July and October exhibiting the most efficient months, corresponding to 90% and 11.3%, respectively.

Keywords