MATEC Web of Conferences (Jul 2014)

Computational Analyses of Passive Wet Gas Separation in Branched Piping

  • Pao William,
  • Hashim Fakhruldin M,
  • Ming Low Huei

DOI
https://doi.org/10.1051/matecconf/20141303009
Journal volume & issue
Vol. 13
p. 03009

Abstract

Read online

Understanding the behavior of two-phase flow through a T-junction is very important as it could potential contribute to massive cost saving in partial phase separation. The objectives of this paper focuses on the effect the inlet flow conditions on two-phase split efficiency under constant pressure gradient, and the effect of averaged bubble diameter on the mass flow split at the side arm outlet Via computational fluid dynamics tool, preliminary investigation found that beyond side to main arm diameter ratio of 0.75, there is a drop of separation efficiency. The change of fraction of gas taken off is almost linearly and negatively proportional to the unit increment of initial gas saturation. When the side to main arm diameter ratios equal to 0.5 and 0.75, the fraction of gas taken off is almost similar as far as the initial gas saturation is concerned.