Applied Sciences (Feb 2022)

Generation of Intense and Temporally Clean Pulses—Contrast Issues of High-Brightness Excimer Systems

  • Sándor Szatmári,
  • Rita Dajka,
  • Gábor Almási,
  • István B. Földes

DOI
https://doi.org/10.3390/app12042064
Journal volume & issue
Vol. 12, no. 4
p. 2064

Abstract

Read online

In high-brightness excimer systems, the direct amplification of short pulses allows temporal filters to be integral parts of the ultraviolet (UV) amplifier chain, where the only origin of the noise is the amplified spontaneous emission (ASE), generated by the amplifier(s) following the filter. The ASE, however, develops faster than the short main pulse; in this paper, the dynamic short- and long-pulse amplification properties of KrF, XeCl and XeF excimers are studied, with special emphasis on the temporal contrast. It was found that, beyond the saturation of amplification, the relaxation of the B state in KrF, together with the contribution of the absorption of the transiently populated X state in XeCl and XeF, are the main limitations for both the extraction efficiency and the contrast. For all excimers, the stimulated transition rates and the dependence of the achievable contrast on the level of saturation were derived. Local quantities were introduced to characterize the deterioration of the contrast for a unit gain length of KrF amplifiers. A KrF power amplifier of limited gain (G ≈ 3), following the newly introduced nonlinear Fourier filter, is capable of reaching contrast levels beyond the previously reported 1011–1012.

Keywords