Scientific Reports (Mar 2017)

Pd/ZnO nanorods based sensor for highly selective detection of extremely low concentration hydrogen

  • Mohit Kumar,
  • Vijendra Singh Bhati,
  • Sapana Ranwa,
  • Jitendra Singh,
  • Mahesh kumar

DOI
https://doi.org/10.1038/s41598-017-00362-x
Journal volume & issue
Vol. 7, no. 1
pp. 1 – 9

Abstract

Read online

Abstract We report highly hydrogen selective Pd contacted ZnO nanorods based sensor detecting low concentration even at low operating temperature of 50 °C. The sensor performance was investigated for various gases such as H2, CH4, H2S and CO2 at different operating temperatures from 50 °C to 175 °C for various gas concentrations ranging from 7 ppm to 10,000 ppm (1%). The sensor is highly efficient as it detects hydrogen even at low concentration of ~7 ppm and at operating temperature of 50 °C. The sensor’s minimum limit of detection and relative response at 175 °C were found 7 ppm with ~38.7% for H2, 110 ppm with ~6.08% for CH4, 500 ppm with ~10.06% for H2S and 1% with ~11.87% for CO2. Here, Pd exhibits dual characteristics as metal contact and excellent catalyst to hydrogen molecules. The activation energy was calculated for all the gases and found lowest ~3.658 kJ/mol for H2. Low activation energy accelerates desorption reactions and enhances the sensor’s performance.