Journal of Cardiothoracic Surgery (Dec 2022)

Delayed aortic regurgitation after TEVAR procedure: a case report

  • Soo Jin Park,
  • Seungwook Lee,
  • Jeong A Son,
  • Seungji Hyun,
  • Do Jung Kim,
  • Sang Hyun Lim,
  • You Sun Hong

DOI
https://doi.org/10.1186/s13019-022-02083-3
Journal volume & issue
Vol. 17, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Background Acute aortic regurgitation (AR) is uncommon condition and usually results in an emergent situation because the left ventricle does not adapt quickly due to a sudden increase in end-diastolic volume caused by the regurgitant flow. Thoracic endovascular aortic repair (TEVAR) is a procedure that places a stent-graft on the lesion of thoracic aorta through a minimally invasive approach. Case presentation Here we report that a catheter-induced aortic valve injury associated with TEVAR can cause delayed AR, exemplified by the case of a patient who developed acute AR 42 months after TEVAR. For this, aortic valve replacement was performed and the patient was discharged without complications. Conclusion Our results demonstrate that when a catheter-related procedure is performed around the aortic valve, slight injury of the valve can cause aortic insufficiency even 3 years after surgery. Consequently, when performing a catheter-related procedure around the aortic valve, special attention is always required.

Keywords